SECTION 4: INSTALLATION REFERENCE 61
EPI800 Manual.doc EPI 800 MANUAL 2001 Vision Microsystems Inc.
Step 8. With the cable and shield still lying flat, trim the other end of the
shield so that the cable extends beyond it by ¾ INCH.
Step 9. Remove the adhesive’s protective paper strip from the large flap.
First fold the small flap over the cable and next the large flap
making sure it is aligned over the small flaps metalized area.
Now press it down firmly to insure proper bonding to the small
flap.
Step 10. Install an appropriately sized ring terminal onto shield wire
tail for attachment to ground on the DPU mounting bolt.
WARNING: Be sure all loose strands of the metalized shield are
removed from ALL trimmed edges or possible damage to the
system may result.
Step 11. After installation on the indicators, inspect finished
assembly to insure no shielding can touch the cable connectors.
This may cause a short and create disruption or damage to the
indicators. If this appears likely, then the shielding should be
moved or trimmed back from the connector and secured to the
flat cable with electrical tape or electrical RTV at the problem
locations.