43
ВАРШ.201219.009РЭ
No video image in the web inter-
face
Product malfunction
Reboot the product pro-
grammatically (in the web
interface) or by removing
and connecting the power
cable.
If it does not help, save the
settings and reset to factory
settings (resetting the net-
work configuration is not
necessary), then import the
settings.
Required web browser
plugins not installed
Install the plugins sug-
gested by the browser.
License plate not recognized
Lens out of focus
Enable automatic focus or
set manually.
Recognition region is not
set
In the Additional settings
>> LPR >> Settings tab,
set the recognition region.
No license
Enter the license key on the
tab: Additional settings >>
LPR >> Settings
The camera is not visible on the
network
No connection
Check connections
The network settings are in-
correct
Reset the camera to factory
settings. Respecify the
settings.
Damaged cable
Replace cables, check the
correctness of the cable
preparation.