EasyManua.ls Logo

vitapur Pro Soft VWS296GR - Troubleshooting Guide

vitapur Pro Soft VWS296GR
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
PROBLEM CAUSE SOLUTION(S)
1. Softener fails to
regenerate.
A. Powersupplytounithasbeeninterrupted. A. Checkpowersupply.
B. Regenerationcyclesetincorrectly. B. Resetregenerationcycles.
2. Regeneration time
is not correct.
A. Timeofdaynotsetcorrectly.
Checkprogramandresettimeofday.
B. Powerfailurelastedmorethan3days.
3. Softener supplies
hard water.
A. Bypassvalveopenedorleaking. A. Closeorrepairthebypassvalve.
B. Nosaltinbrinetank.
B. Addsalttothebrinetankandmaintainsalt
 levelabovewaterlevel.
C. Injectorisplugged. C. Changeorcleantheinjector.
D. Regenerationcyclesnotcorrect.
D. Setthecorrectregenerationcyclesinthe
 program.
4. Unit uses too much salt.
A. Impropersaltsetting. A. Checksaltusageandsaltsetting.
B. Excessivewaterinbrinetank. B. SeeproblemNo.6
5. Excessive water in
tank.
A. Toolongrefillingtime. A. Resetcorrectrefillingtime.
B. Toomuchwaterinbrinetankafterbrinedraw.
B. Checktheinjectorandmakesurenoforeign
 materialinbrinetubingpluggingflow.
C. Safetybrinevalvebreakdown. C. Repairorreplacesafetybrinevalve.
6. Control Valve cycles
continuously.
A. Locatingsignalwiringbreakdown. A. Checkandconnectlocatingsignalwiring.
B. Controllerisfaulty. B. Replacethecontroller.
C. Timeofregenerationstepsweresettozero. C. Checkprogramsettingandreset.
7. Drain line flows
continuously.
A. Powerlosswheninbackwashorfastrinse.
A. Adjustvalvetoservicepositionorturnoff
 bypassvalveandrestartwhenpowerisback
 on.
8. Salt water taste
in the soft water.
A. Foreignmaterialininjectororinjectorfailstowork. A. Cleanandrepairinjector.
B. Brinevalvecannotshut-off. B. Repairbrinevalveandcleanit.
C. Timeoffastrinsetooshort. C. Extendfastrinsetime.
9. Water capacity
decreases.
A. Regenerationcyclenotcompleted. A. Completeafullregenerationcycle.
B. Saltsettingnotadequate. B. Readjustbrinedrawtime.
C. Softenersettingforcapacitynotcorrect.
C. Accordingtothetestofoutletwater,recount
 andreset.
D. Rawwaterqualitydeterioration.
D. Regenerateunitmanuallythenresetthe
 regenerationcycle.
10. Water capacity
decreases.
A. Thewiringoffrontpanelwithcontrollerfailsto
 work.
A. Changethecablebetweenscreenandcontrol
 panel.
B. Poweradapteriswetordamaged. B. Checkandreplacethepoweradapter.
C. Electricalpowersupplyinterrupted. C. Checkthepowersupplyison.
11. Nothing displays on
LED screen.
A. Thewiringoffrontdisplaypanelwithcontrollerfails
 towork.
A. Checkandreplacecable.Connectingdisplay
 screentovalve.
B. Poweriscutoff. B. Checkthecablesandmainpowersupply.
12. Only “E1” shows on
the screen and is
flashing.
A. Thelinebetweenthelocatingboardandmain
 controlboardisdamaged.
A. Replacecablebetweenthelocatingboardand
 maincontrolboard.
B. Motorisdamaged. B. Replacemotor.
13. Only “E2” shows on
the screen and is
flashing.
A. Thecablebetweenthelocatingboardandmain
 controlboardisdamaged.
A. Replacewiringharness.
14. Only “E3” or “E4”
shows on the screen
and is flashing.
A. Controlboardisfaulty. A. Replacecontrolboard.
TroubleshooTing guide