5. R O U T E R DESIGN
• F o r e v e r y cables w e rec omm en d to bind the bunch according to the followi n g picture, w e
rec o mm e nd for this use:
– Length of the bunch (combination of power supply and data cables) can be max-
imum 1,5 m. If the length of data cables e x c e e d s 1,5 m or in the e v e n t of, the
cable leads toward s the switch – board. W e re com men d installing o v e r – v o l t a g e
protectors (surge suppressors).
– With data cables they mustn’t carry cables with ret i cu l ar t e n s i o n ∼ 230 V/50 Hz.
– All signals to sensors must be twisted pairs.
Figure 14: Cable routing Figure 15: Cable routing for SL v e r s i o n
• Sufficient space must be left before individual connectors fo r handling of cables,
Figure 16: Space in front of connectors Figure 17: Space in front of connectors – SL
• F o r correct function of the router w e rec o mm end to use in the switch-board earth-bonding
distribution frame fo r grounding of power supply of router, data cables and antenna.