123456789012345678901
123456789012345678901
123456789012345678901
123456789012345678901
123456789012345678901
●*
●*
●
●
●*
●
1)
●
2)
50 Hrs
250 Hrs
500 Hrs
1000 Hrs
2000 Hrs
12 months
6. Twin Disc reverse gear:
Remove and clean
reverse gear oil screen.
7. Replace oil filter in
reverse gear Twin Disc
MG507(A)-1 with trolling
valve.
8. Lubricate release
bearing on
disengageable clutch
(if fitted).
9. Lubricate disengageable
clutch (if fitted).
10. Check/adjust disengage-
able clutch (if fitted).
11. Replace filter for
crankcase ventilation.
1) TAMD63 and TAMD72.
2) TAMD71.
* Note: Special recommendations apply for new or reconditioned
engines. See instructions “Running-in” on page 4.
46
–
–
–
–
41
Remove plug and oil screen. Clean screen and refit parts. Start engine (after filing
with oil) and check for leaks.
Remove clamp (1). Remove cover and take out filter. Clean filter casing and fit a
new filter. Check oil level (point 3 above).
Note: 50th hour applies when the clutch is manouvered often (15–20 times a day
or more). In other cases every 500th hour. Lubricate sparingly so that no grease
escapes. Use lithium-based lubricating grease: Mobilux EP2, Statoil Uniway
EP2N, Texaco Multifak EP2, Q8 Rembrandt EP2.
Lubricate inner support bearing (when a grease nipple is fitted), main bearings,
disengaging shaft and moving parts of clutch mechanism. Lubricate sparingly
(20–30 g for main bearings). Quality: see point 8 above. A few drops of oil on
inner link arms.
WARNING! Engine must be stopped when adjustment is carried out.
Remove the inspection cover. Release the catch (A) and turn the adjuster ring (B)
counterclockwise (Rockford/BW), or clockwise (A.P.). Lock the catch. The clutch
plates must not slip after engagement.
Screw on the new filter by hand. Note: Change filter earlier if air and oil mixture
has begun to press out past the valve (1). Check the drain hose (2) is not
clogged.
Rockford/BW
A. P.
No. Action Instructions Info.
pge.