10 Troubleshooting DPU 130Le
95
Operator's manual
8 Error
Air cleaner
Air cleaner sensor is defective. Have the machine repaired. *
Air cleaner sensor electrical
connection is defective.
Check the electrical connection
of the air cleaner sensor. *
9 Shutdown
Oil pres. sw.
Oil pressure switch or electrical
connection is defective.
Have the machine repaired. *
10 Error
Charge control
Charge control or electrical
connection is defective.
Have the machine repaired. *
11 Error
Charge con./Gen.
Generator, charge control, or
electrical connection is
defective.
Have the machine repaired. *
12 Shutdown
Overload
Machine is overloaded as
ground cannot be further
compacted.
Deactivate the machine and
then reactivate it.
To prevent overload, observe
the following rules:
Avoid operating on ground
that cannot be further
compacted.
Reduce compacting
performance by tilting the
remote control lever less.
Switch from fast to slow
operation.
13 Machine
Overload
Machine is overloaded as
ground cannot be further
compacted.
To prevent overload, observe
the following rules:
Avoid operating on ground
that cannot be further
compacted.
Reduce compacting
performance by tilting the
remote control lever less.
Switch from fast to slow
operation.
14 Shutdown
Overload sensor
Overload sensor or electrical
connection is defective.
Have the machine repaired. *
15 IR transfer
Address comp.
No malfunction. Transmission
channel is coordinated between
the remote control and the
machine.
—
16 IR transfer
Wrong sender
Wrong remote control type. Use correct remote control type.
Error
code