Operation
GPi 3200 I 4300
4.18 Using AC Power
Prerequisites Verify that the engine is operating.
Verify that the voltage displayed on the LCD (j) is approximately 120V.
Turn off the equipment to be connected to the generator.
Confirm that the equipment to be connected to the generator does not exceed
the maximum rated power output and specifed amperage.
WARNING
Electric shock hazard. Failure to properly ground the generator could lead to
electrical sparks, especially
if
the connected electrical equipment is grounded.
Make sure the generator is properly grounded. See Grounding the Generator.
Engine switch Leave the engine switch {h)
in
the RUN position while the machine is operating.
position
Connecting
equipment
0
'E::::n
~t(GJ0]
we
_gr008631
1.
Insert the equipment plug into the 20A receptacle (b) or the 30A twist-lock
receptacle (c).
Note:
To
use the 30A twist-Jock receptacle, insert the plug into the receptacle
and
turn it clockwise to the
LOCK
position.
2.
Turn on the power switch for the equipment.
Overload fault Excessive current draw on the generator will cause an overload fault. When this
fault occurs, AC power is cut off and
O_Lod
displays on the LCD.
To
clear an overload fault, stop the engine immediately and remedy the overload
condition. Then re-start the engine.
W4CKER
NEUSON
40 wc_tx001875gb.fm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson GPi 3200 and is the answer not in the manual?

Wacker Neuson GPi 3200 Specifications

General IconGeneral
BrandWacker Neuson
ModelGPi 3200
CategoryPortable Generator
LanguageEnglish

Related product manuals