102
EN
Calibration mode
Hold the TEMP. and MAX/MIN key together for 5 seconds to enter calibration
mode.
Press the WIND/+and PRESSURE/key to adjust values.
Press the SET key to conrm & move to the next item.
Press the ALARM key to reset any adjusted value.
Press the LIGHT /SNOOZE key at any time to exit.
Calibration order:
1. Indoor temperature offset calibrated (range +/-5˚C, default: 0 degrees)
2. Indoor humidity offset calibrated (range +/-10%)
3. Outdoor temperature offset calibrated (range +/-5˚C, default: 0 degrees)
4. Outdoor humidity offset calibrated (range +/-10%)
5. Absolute pressure offset calibrated (range +/-50hpa)
6. Wind direction offset calibrated (adjust by degree)
7. Wind speed factor adjust, default 100% (range 50% to 150%)
8. Rain factor adjust, default 100% (range 50% to 150%)