EasyManua.ls Logo

WAM SILOTOP zero - 6.3 Long shut-downs of the equipment; 6.4 Reuse after long shut-down

WAM SILOTOP zero
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.0 INFORMATION REGARDING USE
2
FIL.SILOTOP_zero.--.M.A4.0722.EN Issue: A4
07.22
30
6.3 Long shut-downs of the equipment
When the equipment has to remain unused for long periods, proceed as described below.
1) Avoid damp and salty environments during equipment shut-downs.
2) Place the equipment on wooden pallet.
3) Set the equipment in safety condition before operating it.
4) Before using the equipment, check the condition of the electrical and pneumatic systems and all the parts
the working of which may be a󰀨ected by prolonged shut-downs.
5) Run a complete cleaning cycle before activating the lter.
6.4 Reuse after long shut-down
Important
If the equipment is to be used in di󰀨erent conditions and with materials other than the previous applica-
tion, ensure the “Permitted use” indications are complied with.
Before reusing the lter after a long shut-down, proceed as described below:
1) Check the main nuts and bolts to make sure they are tightened properly.
2) Start up the equipment (see “Production Start-up”).