133V2.0/02.11
Descriptionofthememoryfunctions
ENGLISH
1.Determiningthedurationoftherecordingintervalfor
RECCONFIG2000PTS:
Time Channels Meas-
ured
variable
Number
ofmeas-
urement
values
Durationofthe
recordinginterval
60 s
60.000 ms
4 (SCPT) °C
bar
4 x 60
4 x 2.000
60.000 ÷ 2.000 =
30 ms
Stored measurement points 8.240
30 s
30.000 ms
4 (SCPT) °C
bar
4 x 30
4 x 2.000
30.000 ÷ 2.000 =
15 ms
Stored measurement points 8.120
60 s
60.000 ms
2 (SCPT)
1 (SCFT)
1 (SCRPM)
°C
bar
L/min
RPM
2 x 60
2 x 2.000
1 x 2.000
1 x 2.000
60.000 ÷ 2.000 =
30 ms
Stored measurement points 8.120
40 s
40.000 ms
2 (SCPT)
1 (SCFT)
1 (SCRPM)
°C
bar
L/min
RPM
2 x 40
2 x 2.000
1 x 2.000
1 x 2.000
40.000 ÷ 2.000 =
20 ms
Stored measurement points 8.080