4
HMI OPERATION
Exit 13:38 Select
Sub
LOC
0rpm
Warning
Incorrect
password
try again
Press Any Key
Figure 4.10: Inverter alarm visualization mode
NOTE!
Notes do not generate events such as inverter stopping.
4.5.3 Error Log
The parameter P0067 keeps the information on the inverter last 100 occurred errors, according to Figure 4.10 on
page 4-11.
Exit 13:38 +Info.
A0008
LOC
0rpm
Error Log
Date
A/F
No
Hour
[01] A0008 18/08/2015 13:38
[02] A0110 17/08/2015 07:43
[03] F0090 16/08/2015 06:33
[04] F0025 15/08/2015 05:23
[05] F0090 14/08/2015 04:13
[06] F0013 13/08/2015 03:13
Figure 4.11: Error log P0067
In order to visualize more information regarding the error, such as its description and the status of the inverter at the
moment it occurred, it is necessary to select the [+Info] option through the corresponding softkey (refer to Figure
4.11 on page 4-11).
Exit 13:38
Sub
LOC
0rpm
A0110
Last Error
Motor overtemperature
alarm
Date: 08/04/2015
Hour: 17:11
Status: Acceleration Ramp
Figure 4.12: More information about the error
MVW3000 | 4-11