WG20 Geared Motors | E-29
15. Mounting positions and lubricant capacity
15.1. Helical gear units C
Mounting positions and position of venting and oil drain screw
By default, gear units are only equipped with venting and oil drain screw from gear size C07!
Lubricant capacity
Stages Type with housing in foot execution
Mounting positions
M1 M2 M3 M4 M5 M6
2
C00 0.1 l 0.3 l 0.3 l 0.3 l 0.2 l 0.2 l
C01 0.1 l 0.4 l 0.4 l 0.3 l 0.3 l 0.3 l
C03 0.3 l 0.7 l 0.6 l 0.6 l 0.5 l 0.4 l
C05 0.4 l 1.2 l 1.1 l 1.2 l 0.8 l 0.7 l
C06 0.5 l 1.6 l 1.6 l 1.5 l 1.1 l 1.0 l
C07 1.6 l 3.8 l 3.6 l 4.6 l 2.8 l 2.4 l
C08 3.4 l 7.1 l 6.7 l 8.9 l 4.7 l 5.4 l
3
C03 0.2 l 0.7 l 0.7 l 0.6 l 0.4 l 0.4 l
C05 0.3 l 1.1 l 1.1 l 1.1 l 0.7 l 0.7 l
C06 0.3 l 1.5 l 1.6 l 1.4 l 1.0 l 0.9 l
C07 1.5 l 3.6 l 3.5 l 4.4 l 2.6 l 2.4 l
C08 3.3 l 6.9 l 6.6 l 8.8 l 4.8 l 5.1 l
Stages Type with housing in ange execution
Mounting positions
M1 M2 M3 M4 M5 M6
2
C00 0.1 l 0.3 l 0.4 l 0.3 l 0.2 l 0.3 l
C01 0.2 l 0.4 l 0.5 l 0.5 l 0.3 l 0.4 l
C03 0.4 l 0.8 l 0.7 l 0.8 l 0.5 l 0.5 l
C05 0.6 l 1.3 l 1.2 l 1.5 l 0.9 l 1.0 l
C06 0.9 l 1.8 l 1.9 l 2.2 l 1.9 l 1.4 l
C07 1.6 l 3.8 l 3.6 l 4.6 l 2.8 l 2.4 l
C08 3.4 l 7.1 l 6.7 l 8.9 l 4.7 l 5.4 l
3
C03 0.3 l 0.7 l 0.7 l 0.7 l 0.5 l 0.5 l
C05 0.5 l 1.2 l 1.3 l 1.5 l 0.9 l 1.0 l
C06 0.8 l 1.7 l 1.8 l 2.1 l 1.2 l 1.3 l
C07 1.5 l 3.6 l 3.5 l 4.4 l 2.6 l 2.4 l
C08 3.3 l 6.9 l 6.6 l 8.8 l 4.8 l 5.1 l
M1
M2
M3
M4
M5M6
Position of the venting screw
Position of the oil drain screw
1) Position ange execution
2) Position foot execution
1)
2)
1)
2)