19
Before stopping the engine, gradually reduce the load, then gradually reduce
the engine speed to 600~1000 r/min.
To stop the engine from the main control panel, press the emergency stop
button provided on the display monitor.(Refer gure 4.18)
Figure 4.18
And to stop the engine from the remote monitor, push the stop button (Refer
Fig. 4.19)
Figure 4.19
After stopping the engine, turn off the power supply to the control panel. To shut
down the engines on emergency, press the emergency stop button provided on the
control panel OR press the fuel cut off lever on the fuel injection pump OR shut off
the main fuel supply valve near to the main fuel tank.
4.3.8 Running in period
The engine components are made of materials with different thermal expansion
and stability. It should be gradually set to the normal engine operating temperature.
First 60 hours of operation is considered as running in period. During this period,
engine needs to be run with care at normal load (80 to 85% maximum). Aggressive
operation and loading during running in will disturb thermal stability and leads to
shortened engine life.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEICHAI WP12 and is the answer not in the manual?

WEICHAI WP12 Specifications

General IconGeneral
Engine ModelWP12
Number of Cylinders6
Displacement11.596 L
Bore x Stroke126 mm x 155 mm
Compression Ratio17:1
Max Torque2100N.m
Weight1100 kg
Fuel SystemHigh Pressure Common Rail
Fuel Consumption≤195g/kWh