21
ProCommander
®
AX Pin Assignment
ATTENTION!
The 24V may not be exceeded in any case. Thus,
if the power supply has a ripple in the voltage, the
peak voltage must not exceed 24V.
ANALOG IN 1-4/ DIGITAL IN 1-8
The ProCommander
®
AX has four analog and eight digital
inputs for connecting external dry contacts for the purpose of
logic evaluations or show starts. Inputs 1-4 are analog inputs,
which can evaluate voltages from 0-10V with a 12-bit resolution.
The query of the inputs is also available via the "GET" commands
(see ASCII chart).
A level change of individual inputs can trigger show starts,
if shows are stored on a microSD card. The assignment of the
shows to the different inputs can be defined in the Control.ini
file. Please refer to chapter "Control.ini" for more information.
ANALOG 1-4 (0-10V Output)
The ProCommander
®
AX has four 0-10V analog outputs
with a 12-bit resolution are available. The maximum current per
output is 10mA. Additional output current available from our
Pro I/O
TM
Analog 8.
DIGITAL OUT 5-8/ PWM 5-8
The ProCommander
®
AX has four digital open collector
outputs. Outputs 5-8 can be utilized additionally as PWM
outputs. Switching to PWM output is done automatically by the
ProCommander
®
AX, as soon as the channel is controlled by

Table of Contents