2 Basic Commissioning
Through this section, you can quickly know the following basic commissioning
processes for NK300CX:
1. Switch the system configuration.
2. Adjust I/O port polarity.
3. Set commissioning parameters.
4. Adjust the axis direction.
5. Return to the machine origin.
6. Set the workbench travel.
2.1 Switch the System Configuration
This operation is used to check if the default system configuration is the desired one,
and change it according to the structure of the machine tool if it is not the desired
one when the system is installed at the first time.
At present, NK300CX supports the following configurations:
Three-axis configuration
Four-axis configuration
Five-axis configuration
To switch system configuration, do the following:
1. To enter into System interface, press 1.
2. Press F3, enter the manufacturer password. Configuration Manager dialog
box pops up:
The current system configuration is in blue at the bottom of the dialog box.