ONE
13
SERVICE PROGRAMMING_1B
· F.01 – Boiler lling time-out alarm
· F.04 – Enabling/Disabling shot timer
· F.03 – Level probe sensitivity
To change the brewing mode, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When ‘F.02’ is shown on the display, enter by pressing K3.
3. Within 5s, select with K2 and K3 the brewing mode:
To change the machine’s level probe sensitivity, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When ‘F.03’ is shown on the display, enter by pressing K3.
3. Within 5s, select with K2 and K3 the level probe sensitivity between ‘MAX’, ‘MED’ and ‘MIN’. ‘MED’
is set by default.
4. After 5s the display will go back the service programming menu.
To enable or disable the brewing shot timer on the group display, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When ‘F.04’ is shown on the display, enter by pressing K3.
3. Within 5s, select with K2 and K3 the select between ‘On’ or ‘O’.
4. After 5s the display will go back the service programming menu.
a. On (Control mode): For machines with control pad installed.
b. O (Lever mode): For machines with manual group lever.
4. After 5s the display will go back the service programming menu.
Note:
For ONE 1B models, access to the technical menu and set this setting into ‘O’.
i
· F.02 – Brewing mode
To change the machine’s steam boiler lling time-out alarm, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When ‘F.01’ is shown on the display, enter by pressing K3.
3. Within 5s, select with K2 and K3 the boiler lling time out. 120s is set by default.
4. After 5s the display will go back the service programming menu.