ROUTINE MAINTENANCE SCHEDULE
· Service intervals
Main components Part No.
Months (Cycles)
12 (12500) 24 (25000) 36 (37500) 48 (50000)
Boiler
Vaccum valve 65000210 Check Check Check Replace
Boiler lling solenoid
valve
60000126
(230V)
60000127
(115V)
Replace
Boiler upper raccord 30000200 Check Check
Boiler lower raccord 30000203 Check Check
Safety Valve 65000115 Check Check
Brewing group
Shower 75000010 Replace Replace Replace Replace
Group head gasket
75000081
75000083
Replace Replace Replace Replace
Taps
Steam tap 15000401 Clean Replace
Water tap 15000411 Replace
Motor-pump
Vibration Pump
10036421
(230V)
60000047
(110V)
Replace
Rotary Pump 60000021 Replace
Non return valve 65000011 Replace
Pump Bypass Condor 30400055 Check
Important:
Always conduct the 6 month service intervals without delay to ensure excellent performance
of the machine and to ensure full warranty coverage.