INSTRUCTIONS FOR FITTERS
To optimise boiler efciency, carry out the following annual controls:
check the appearance and air-tightness of the gaskets of the gas and combustion circuits;
check the state and correct position of the ignition and ame-sensing electrodes;
check the state of the burner and make sure it is rmly xed;
check for any impurities inside the combustion chamber.
Use a vacuum cleaner to do this;
check the gas valve is correctly calibrated;
check the pressure of the heating system;
check the pressure of the expansion vessel;
check the fan works correctly;
make sure the ue and air ducts are unobstructed;
WARNINGS
Before commencing any maintenance operations, make sure the boiler is disconnected from the power supply.
Afterwards, move the knobs and/or operating parameters of the boiler to their original positions.
28. ANNUAL SERVICING
0808_2601 / CG_2078
Figure 16
WARNING
Pay great attention when dismantling the individual parts of the hydraulic assembly.
Do not use sharp tools, do not apply excessive force when removing the xing clip.