it CALDAIA MURALE A GAS AD ALTO RENDIMENTO
Manuale per l’uso destinato all’utente ed all’installatore
en HIGH PERFORMANCE GAS-FIRED WALL-MOUNTED BOILER
Operating and installation instructions
ru ВЫСОКОПРОИЗВОДИТЕЛЬНЫЙ НАСТЕННЫЙ ГАЗОВЫЙ КОТЕЛ
Руководство по установке и эксплуатации
es CALDERA MURAL DE GAS DE ALTO RENDIMIENTO
Manual para el usuario y el instalador
hu MAGAS HOZAMÚ FALI GÁZKAZÁN
Felhasználói és szerelői kézikönyv
el ΕΠΙΤΟΙΧΙΟΣ ΛΕΒΗΤΑΣ ΑΕΡΙΟΥ ΥΨΗΛΗΣ ΑΠΟΔΟΣΗΣ
Εγχειρίδιο χρήσης για τον χρήστη και τον εγκαταστάτη
ro CENTRALĂ TERMICĂ MURALĂ PE GAZ CU RANDAMENT RIDICAT
Manual de instrucţiuni pentru utilizator şi instalator

Table of Contents

Questions and Answers

  • J
    joneselijahAug 13, 2025
    Why does my Westen Boiler shut down for ignition failure?
    • K
      Karla WilsonAug 13, 2025
      Your Westen Boiler might shut down due to several reasons: no inlet gas pressure, an interrupted ignition switch-flame sensor wire, a faulty or incorrectly positioned flame sensing electrode, a faulty gas valve, or a faulty electronic board. To resolve this, check that the gas valve is open and there is no air in the gas supply circuit, and verify the gas supply pressure. Also, check the wire is uninterrupted and makes good contact with the flame sensing electrode and the ignition switch. Inspect the connections between the gas valve and the electronic board. Finally, ensure the flame sensing electrode is in good condition and in the right position.
  • R
    Rose KimAug 17, 2025
    What to do if my Westen Pulsar E shuts down due to the safety thermostat?
    • J
      jackielivingstonAug 17, 2025
      If your Westen Boiler shuts down due to the safety thermostat, it could be due to no water in the primary circuit (pump blocked or exchanger obstructed), a faulty limit thermostat, interrupted limit thermostat wiring, a faulty CH flow NTC probe, or a faulty electronic board. You can check pump operation by unscrewing the front cap and releasing the pump impeller with a screwdriver and check the pump power input wiring. Inspect the limit thermostat for damage and replace it if necessary. Also, check the continuity of the limit thermostat wiring and check whether the exchanger is clogged.
  • P
    palmermariaAug 21, 2025
    How to fix a flow sensor failure in my Westen Pulsar E Boiler?
    • E
      Elizabeth BatesAug 21, 2025
      A flow sensor failure in your Westen Boiler can occur if the CH flow NTC probe is faulty (circuit open or shorted) or if the CH flow probe wiring is interrupted or shorted. To address this, check the CH flow NTC probe and the continuity of the CH flow probe wiring. Also, make sure the wiring has not shorted.
  • R
    Robert MorrowAug 25, 2025
    What to do if my Westen Pulsar E shows a DHW sensor fault?
    • M
      michelleparsonsAug 25, 2025
      If your Westen Boiler shows a DHW sensor fault, it may be due to a faulty DHW flow NTC probe (circuit open or shorted) or interrupted/shorted DHW flow probe wiring. Check the DHW NTC probe and the continuity of the DHW probe wiring. Ensure the wiring is not shorted.
  • A
    Abigail PadillaAug 28, 2025
    How to resolve a board configuration error in my Westen Boiler?
    • S
      Sean HarrisonAug 28, 2025
      A board configuration error in your Westen Boiler happens when parameter F43 has not been set correctly. To fix this, set parameter F43 with the value indicated in the table in the SETTING PARAMETERS section.
  • H
    Hayden KirkAug 31, 2025
    Why does my Westen Boiler display a fumes NTC probe fault?
    • K
      Karen LeblancAug 31, 2025
      A fumes NTC probe fault in your Westen Boiler may occur if the fumes NTC probe is faulty (circuit open) or if the fumes probe wiring is interrupted. You should check the fumes NTC probe and the continuity of the fumes probe wiring.
  • K
    Kenneth ParrishSep 4, 2025
    What causes an error in the flame amplification circuit of my Westen Pulsar E?
    • C
      Catherine MejiaSep 4, 2025
      An error in the flame amplification circuit of your Westen Boiler can be caused by the electronic board not being earthed or the electronic board being faulty. Check the continuity of the earth connections between the electronic board (X4 connector) and the power supply terminal block.
  • E
    ellisandrewSep 8, 2025
    What causes an error in the gas valve safety circuit of my Westen Pulsar E Boiler?
    • R
      Ryan SmithSep 8, 2025
      An error in the gas valve safety circuit of your Westen Boiler is caused by a faulty electronic board. To resolve this, replace the electronic board.

Summary

SAFETY WARNINGS

DESCRIPTION OF SYMBOLS

Explains various warning symbols used in the manual for user safety.

SMELL OF GAS

Procedure for handling gas leaks, including immediate actions and contacting service.

SMELL OF COMBUSTION FUMES

Procedure for handling combustion fume detection, including ventilation and service contact.

BOILER SERVICING AND CLEANING

Safety instructions for cleaning and servicing the boiler, including power disconnection.

GENERAL PRECAUTIONS

DHW AND HEATING CIRCUIT PRECAUTIONS

Guidelines for DHW circuit quality and heating circuit cleaning before installation.

ENERGY-SAVING TIPS

OPTIMIZING HEATING MODE SETTINGS

Advice on adjusting boiler flow temperature and room temperature for efficiency.

COMMISSIONING THE BOILER

ADJUSTING CH AND DHW FLOW TEMPERATURE

Instructions for setting the central heating and domestic hot water delivery temperatures.

OPERATING MODES

FILLING THE SYSTEM

SWITCHING OFF THE BOILER

GAS CONVERSION

PROLONGED SHUTDOWN & ANTI-FREEZE PROTECTION

FAULTS

ROUTINE MAINTENANCE INSTRUCTIONS

INSTRUCTIONS PRIOR TO INSTALLATION

INSTALLING THE BOILER

INSTALLING THE DUCTS

CONCENTRIC DUCTS INSTALLATION

Guidance on installing concentric flue and air ducts, including bend limitations.

SEPARATE DUCTS INSTALLATION

Instructions for installing separate air and flue ducts, including diaphragm usage.

ELECTRICAL CONNECTIONS

CONNECTING THE ROOM THERMOSTAT

Steps for wiring a room thermostat to the boiler's terminal block.

GAS VALVE

GAS CONVERSION PROCEDURE

Detailed steps for converting the boiler between natural gas and LPG.

REPLACING THE GAS VALVE

Procedure for safely replacing the gas valve component.

GAS VALVE CALIBRATION

Steps for calibrating the gas valve after replacement or conversion.

REPLACING THE ELECTRONIC BOARD

Procedure for replacing the boiler's main electronic control board.

VISUALISATION OF PARAMETERS

PARAMETER SETTINGS

EDITING BOILER PARAMETERS

Guide to accessing and modifying boiler operational parameters.

TROUBLESHOOTING SERVICE FAULTS

ADJUSTMENT AND SAFETY DEVICES

KEY SAFETY DEVICES

Describes essential safety features like limit thermostat, fumes control, and pressure switches.

PUMP AND ANTI-FREEZE FUNCTIONS

Details on pump post-circulation, anti-block, and anti-freeze protection systems.

ANNUAL SERVICING

FILTER CLEANING PROCEDURES

Steps for cleaning the domestic hot water and heating circuit filters.

DHW CIRCUIT SCALE REMOVAL

COMBUSTION PARAMETERS

TECHNICAL SPECIFICATIONS

Westen Pulsar E Specifications

General IconGeneral
BrandWesten
ModelPulsar E
CategoryBoiler
LanguageEnglish