67
Check if valve works properly (no leakages and
water quantity filling ok). If valve does not close
completely, change the valve.
Put two sponges (one upper the chute, one on the
rear of the cabinet) as shown in pictures below.
Troubleshooting & Diagnostic:
No ice production
(no ice in the ice container)
Freezer
compartment too warm.
See the ‘freezer too warm’ chapter.
appliances:
Frozen water incoming chute to
the icemaker (see picture).
Note: this issue could be more
frequent in case of water not
filtered (be sure that customer
replaces regularly the water filter).
appliances:
Frozen water incoming tube to the
icemaker.
To solve this problem, make the rework
procedure as described in the Service
Bulletin 4812 711 40138.