3. Safety
14147933.02 10/2018 EN/DE
WIKA operating instructions model T16
11
3.6 Ex marking
DANGER!
Danger to life due to loss of explosion protection
Non-observance of these instructions and their contents may result in the
loss of explosion protection.
Observe the safety instructions and further explosion instructions in these
operating instructions.
Follow the requirements of the ATEX directive.
Observe the information given in the applicable type examination
certificate and the relevant country-specific regulations for installation and
use in hazardous areas (e.g. IEC 60079-14, NEC, CEC).
Check whether the classification is suitable for the application. Observe the relevant
national regulations.
Model overview of European approvals
Model Ex marking Ignition protection type
BVS 17
ATEX E039 X
IECEx BVS 17.0033X
T16.H-AI
(Head mounting version)
II 1G
II 1D
Ex ia IIC T6 ... T4 Ga
Ex ia IIIC T135 °C Da
Intrinsically safe equipment
T16.R-AI
(Rail mounting version)
II 2(1)G
II 2(1)D
Ex ia [ia Ga] IIC T6 ... T4 Gb
Ex ia [ia Da] IIIC T135 °C Db
Intrinsically safe equipment
T16.x-AC II 3G Ex ic IIC T6 ... T4 Gc X Intrinsically safe equipment
T16.x-AN II 3G Ex nA IIC T6 ... T4 Gc X Non-incendive equipment
T16.x-AE II 3G Ex ec IIC T6 ... T4 Gc Non-incendive equipment

Table of Contents