Wilden T8 - Section 6 - Suction Lift Curves & Data; T8 PLASTIC Air-Controlled; A8 PLASTIC Accu-Flo

Wilden T8
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
WILDEN PUMP & ENGINEERING, LLCWIL-10230-E-02
T8 Plastic Suction Lift Capability
Inlet Air Pressure
0 102030405060708090100
Dry Vacuum
0
2
4
6
8
10
12
14
16
18
20
22
24
26
Meter
0
1
2
3
4
5
6
7
FT H
2
O
PSIG
[BAR] [0.7] [1.4] [2.0] [2.7] [3.4] [4.1] [4.8] [5.5] [6.2] [6.9]
Ultra-Flex™
Diaphragms
Rubber Diaphragms
TPE
Diaphragms
PTFE Diaphragms
SECTION 6A
SUCTION LIFT CURVES & DATA
Suction lift curves are calibrated for pumps operating at
305 m (1,000’) above sea level. This chart is meant to be
a guide only. There are many variables which can affect
your pump’s operating characteristics. The number of intake
and discharge elbows, viscosity of pumping fluid, elevation
(atmospheric pressure) and pipe friction loss all affect the
amount of suction lift your pump will attain.
SECTION 6B
SUCTION LIFT CURVES & DATA
Suction lift curves are calibrated for pumps operating at
305 m (1,000’) above sea level. This chart is meant to be
a guide only. There are many variables which can affect
your pump’s operating characteristics. The number of intake
and discharge elbows, viscosity of pumping fluid, elevation
(atmospheric pressure) and pipe friction loss all affect the
amount of suction lift your pump will attain.
A8 Plastic Accu-Flo™ Suction Lift Capability
Inlet Air Pressure
0 102030405060708090100
Dry Vacuum
0
2
4
6
8
10
12
14
16
18
20
22
24
26
Meter
0
1
2
3
4
5
6
7
FT H
2
O
Rubber / TPE
Diaphragms
Ultra-Flex™ /
Diaphragms
PSIG
[BAR] [0.7] [1.4] [2.0] [2.7] [3.4] [4.1] [4.8] [5.5] [6.2] [6.9]
The solenoid was running at 150 strokes / minute.
Actual suction lift may vary with different pump speeds.