88
4 Safety instructions
General notes
1. At the end of the working day always ensure that the shut-off device on the water pipe supply-
ing the machine is closed and the main power switch to which the machine is connected is
switched off and/or the plug is removed from the socket.
2. The component-tested safety devices fitted, prevent inadmissable pressure and temperature
rise in the boiler. If the safety valve is activated, the machine should be switched off immedi-
ately at the customer’s main switch. Switch off the machine if a boiler malfunction occurs.
Contact the WMF customer service department and do not switch the machine on again until
the fault has been remedied.
3. This machine is not for use out of doors. In case of freezing the machine should be drained
beforehand to prevent frost damage.
4. Never spray the machine with a hose or steam jet. Clean the surface by wiping with a damp
cloth, or use beverages from our WMF care range.
5. The unit must stand safe at a ground level, on a horizontal and stable base.
Machine shutdown – holidays
1. If the machine is to be shut down for an extended period, a general cleaning should be carried
out beforehand and the grouts collector must be emptied. If there is any risk of freezing, the
machine should be drained beforehand to prevent frost damage. In such cases, call in the
WMF customer service personnel in good time.
2. After several weeks of shutdown for holidays, we recommend that the fully automatic cleaning
program be run at least twice before the machine is started up again.
Hot water boiler data - see rating plate
The hot water boiler complies with the Pressure Equipment Directive 97/23/EC – Category 1,
Module A.
The hot water boiler is subject to neither notification nor licensing. Each hot water boiler is sub-
jected to hydrostatic tests before delivery to the customer.
The German regulation governing steam boilers and the associated technical rules require the
owner / operator of such plants to ensure that the safety facilities are carefully serviced and in-
spected.
The machine / unit complies with all the relevant regulations.
The owner / operator must ensure that the electrical equipment and systems are in safe working
order.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WMF combiNation S/S4/ESeries 8600 and is the answer not in the manual?

WMF combiNation S/S4/ESeries 8600 Specifications

General IconGeneral
BrandWMF
ModelcombiNation S/S4/ESeries 8600
CategoryCoffee Maker
LanguageEnglish

Related product manuals