ERROR CODE POSSIBLE CAUSE TEST / ACTION
SENSOR CAL
CONTROL COM
RELAY CAL
RELAY STUCK
COOL FAN
Analog to Digital error
during calibration phase
Communication lost with
the oven controller
Relay phase calibration
failed the timing problem
with the relay on the relay
board
Power relay shorted -
sensed as being closed
when it should be open by
current sensor on the
oven controller
Cooling fan apparency
switch is reporting cooling
fan failure. Could be a
failure either of the cool-
ing fan or fan apparency
switch
Replace Oven Controller
Check flat flex cable
between control panel
assembly and oven con-
troller for bad connection.
Replace Oven Controller.
Replace relay board ONLY if
the error is noted for consec-
utive times when in diagnos-
tic mode
Replace Relay Board
Check fan apparency switch,
may have to make an adjust-
ment. Ohm cooling fan,
replace if defective.
ERROR CODE CHART