PAGE 21
Ohm Testing Elements at Relay Board
This procedure will allow the service technician to ohm any of the ele-
ments directly at the relay board.
At the relay board, pull the wire off of the terminal DLB/E11. This is
done to keep from ohming the relay board. It does not take the High
Limit out of the equation, but if the technician DOES NOT get an ohm
reading from the DLB lead to all of the element leads, then, there is a
problem with the High Limit.
To eliminate the High Limit when taking ohm readings, the MDL cover
will need to be removed. Then, remove the wire from High Limit
switch that goes to the elements. Now, take the ohm reading from
that wire at the High Limit to the desired element wire at the relay
board.
Right Convection Element: PR5/E5 to DLB/E11 wire
Left Convection Element: PR2/E5 to DLB/E11 wire
Outer Bake Element: PR4/E8 to DLB/E11 wire
Inner Bake Element: PR3/E6 to DLB/E11 wire
Bake Stone Element: PR6/E10 to DLB/E11 wire
Broil Element: PR1/E4 to DLB/E11 wire