EasyManua.ls Logo

World Cat 280DC-X - 10.1.4 Freshwater System; 10.1.5 Seacocks

Default Icon
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2020 World Cat 280DC-X Owner’s Manual
50
10.1.4 Freshwater System
The freshwater pump is located in the port side mechanical room. The pump is connected to the 17 gallon
freshwater tank located a of the port fuel tank. The tank is lled through a ng located at the
port side transom.
Similar to residenal well pumps, the freshwater pump pressurizes the system to 60 psi. then shuts down
unl the pressure drops below that level. Most owners leave the pump “ON” throughout the day, and use
the system when necessary. On the 280DC-X, the freshwater pump feeds the pull out shower located on
the a transom wall, freshwater wiper rinse and the marine head. To view the layout of the water systems
see the drawing in secon 10.4.5.
10.1.5 Seacocks
2018 World Cat 280CC-X Owners Manual
Page 67
battery management panel through the hull harness and receive power from the breakers on
the right side of the panel. These breakers are constantly energized and ensure the safety of
your boat even when the battery switches are in the “off” position. The pumps can be manually
engaged using the switch at the dash.
The forward bilge pumps are accessible through ______; the aft bilge pumps are located in the
port and starboard mechanical rooms.
Inspect the operation and condition of your bilge pumps regularly. Activate the pump by lifting
the float switch. Once the float switch is released the pump should shut off. It is important to
keep the bilge area clean and free of debris, which may prevent proper operation of the float
switch, and cause damage to the pump.
10.1.4 Freshwater System
The freshwater pump is located in the port side mechanical room. The pump is connected to the
17 gallon freshwater tank located aft of the port fuel tank. The tank is filled through a fitting
located at the port side transom.
Similar to residential well pumps, the freshwater pump pressurizes the system to 60 psi. then
shuts down until the pressure drops below that level. Most owners leave the pump “on”
throughout the day, and use the system when necessary. On the 280CC-X, the freshwater
pump feeds the pull out shower located on the aft transom wall, freshwater wiper rinse and the
marine head. To view the layout of the water systems see the drawing in section 10.4.7.
10.1.5 Seacocks
OPEN CLOSED
Ball valves (seacocks) are installed on the water intake for both the livewell and raw water
system. The seacock must be in the open position for these systems to work. When open, the
handle will be parallel to the valve. In the closed position the handle is perpendicular to the
valve (see picture above). World Cat recommends that the seacocks remain in the closed
position when not in use, or when the boat is left unattended to prevent the vessel from taking
Ball valves (seacocks) are installed on the water intake for both the livewell and raw water system. The
seacock must be in the open posion for these systems to work. When open, the handle will be parallel
to the valve. In the closed posion the handle is perpendicular to the valve (see picture above). World Cat
recommends that the seacocks remain in the closed posion when not in use, or when the boat is le
unaended to prevent the vessel from taking on water due to a plumbing failure.

Table of Contents

Related product manuals