9. Repeat steps 1–8 for the inboard side of the pump.
10.Remove the impeller hub sleeve and gasket. Repeat for the inboard side of the pump.
11.Remove impeller assembly from shaft. Heat the impeller and slide it off of the shaft.
Alternatively, press the impeller off of the shaft if a suitable press is available. Wear
insulated gloves when handling hot components.
12.Remove the impeller key.
13.Remove pins and O-rings from each casing wear ring.