EasyManuals Logo

Xylem LOWARA e-SV Series Installation, Operation And Maintenance Manual

Xylem LOWARA e-SV Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
en - Original instructions
e-SV series - Installation, Operation and Maintenance Manual 33
7 Troubleshooting
7.1 Precautions
WARNING:
Maintenance must be done by a technician possessing the technical-professional requirements
outlined in the current regulations.
WARNING:
Observe the safety requirements in the chapters on Use and Operation and Maintenance.
WARNING:
If a fault cannot be corrected or is not mentioned, contact Xylem or the Authorised Distributor.
7.2 The unit does not start
Cause
Remedy
Power supply cut off
Restore the power supply
The thermal overload protection of the motor
has been triggered
Reset the thermal overload protection on the
control panel or the unit
The device that detects the absence of liquid or
minimum pressure has been triggered
Top up the liquid or restore minimum pressure
Power supply cable is damaged
Replace the power supply cable
The capacitor, if present, is faulty
Replace the capacitor
Control panel faulty
Check and repair or replace the control panel
Motor (coil) faulty
Check and repair or replace the motor
7.3 The differential protection device (RCD) is activated
Cause
Remedy
Motor leaking
Check and repair or replace the motor
Unsuitable type of differential
Check the type of differential

Table of Contents

Other manuals for Xylem LOWARA e-SV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem LOWARA e-SV Series and is the answer not in the manual?

Xylem LOWARA e-SV Series Specifications

General IconGeneral
BrandXylem
ModelLOWARA e-SV Series
CategoryWater Pump
LanguageEnglish

Related product manuals