4 Installation
42 03.2018
ba-o.2.6.0-us-1.1-y | A11867501 Rev AA
4.9.3 Protection of equipment
Protective devices include:
Devices for overcurrent protection (fuses, circuit breakers)
Motor protection devices
Overload safety devices
Temperature monitors
Limit switches
The protective devices in the electrical equipment installed in the scope of supply must in
no case be removed, replaced by different devices or bridged.
If a protective device has reacted, the hoist must not be put back in service until the
cause has been determined and eliminated with the assistance of a qualified person.
Overcurrent protection devices
Every hoist must have devices for disconnecting and switching the power supply. This
function is performed by the following devices:
4.9.4 Emergency stop
It must be possible to disconnect the system electrically from the operating position. This
function can be provided by:
Emergency stop button in the control pendant in conjunction with the crane switch
contactor
Main isolator.
4.9.5 Runway conductor disconnecting means
must disconnect the wire rope hoist on all poles,
must be lockable in OFF position,
must be installed in an easily accessible place in the system,
must be marked as such to avoid mistakes.
4.9.6 Disconnect switch
Required for one or more hoists,
must be lockable in OFF position.
4.9.7 Connection fuses
Overcurrent protection devices.
The fuse values must be observed so that the crane switch contacts do not weld if
there is a short circuit and overload protection of lead is ensured.