7 Inspection and maintenance
03.2018 61
ba-o.2.6.0-us-1.1-y | A11867501 Rev AA
7.2 Maintenance intervals
Fig. 71
Periodic inspection
every 12
months *2
Work every 5 years
Work every 10
years
Maintenance table
see page
Brake (20), measure air gap, replace brake disk if necessary
63, 64, 65
Overload safety device (21)
77
Grease rope (22) with brush
101
Grease rope guide (23) with brush
101
Tighten clamping points for electric cables
Oil change (normal mode)
101
Oil change in case of ambient temperatures 131°F and engine rating M7 and higher
101
Periodic inspections including maintenance at least every 12 months, possibly more
frequently if so prescribed by national regulations, to be performed by a qualified person.
*2 Heavy duty or unfavorable conditions (dirt, solvents, multi-shift operation, etc.)
entail a reduction of this inspection and maintenance interval.
NOTICE
Material damage hazard. If increased wear or damage is ascertained when inspecting
or maintaining the hoist, the latter must not be put into operation again until the faults
have been eliminated.
W0792
22
20
23 21
20
W0793
20
W0794

Table of Contents