3.2 Function Modules
USB Memory
3-88
Alarm History File
This section describes the data that is displayed when an alarm history file is checked on a PC.
Alarm History File Format
The following example shows how the CSV file is displayed when it is opened in a text editor.
No. Item Remarks
Index Range: 1 to 100
Alarm Code
Refer to the following manual for details.
MP3000 Series MP3200/MP3300 Troubleshooting Manual
(Manual No.: SIEP C880725 01)
Alarm Details Format Type
Operation error
I/O error
•Other error
Time when alarm occurred yyyy/mm/dd/ hh:mm_ss
Alarm Rack Number
Alarm Unit Number
Alarm Slot Number
Alarm Detail 1
Alarm Details
The information depends on the alarm details format type.
Operation Errors
Alarm detail 1: Error drawing number
Alarm detail 2: Referenced drawing number
Alarm detail 3: Referenced drawing step number
Alarm details 4 and 5: Reserved for system.
I/O Errors
Alarm details 1 to 5: Reserved for system.
•Other Errors
Alarm details 1 to 5: Reserved for system.
Alarm Detail 2
Alarm Detail 3
Alarm Detail 4
Alarm Detail 5
No,Alarm Code,Alarm Detail Format,Date,Rack,Unit,Slot,Detail1,Detail2,Detail3,Detail4,Detail5
1,A101H,I/O error,2000/01/01 00:00_40s,1,0,0,0000H,0000H,0000H,0000H,0000H
2,A30BH,Other error,2000/01/01 00:00_56s,1,0,0,0000H,0000H,0000H,0000H,0000H
