4 Start-Up Programming
YASK AWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide 113
Start-Up Programming
4
Using a Battery for the DC Bus and 24 V Power Supply Unit Option for the Control Circuit
Follow the instructions when using a 24 V Power Supply Unit option for the control circuit and a battery for the main
circuit. The main circuit battery voltage must be higher than 48 Vdc for 200 V and 400 V class drives.
Yaskawa offers a 24 V Power Supply Option for the control circuit that is useful in applications unable to connect to a
backup battery greater than 250 V. Wiring instructions can be found in Figure 62 to Figure 64. For a more detailed
explanation of the 24 V Power Supply Option, refer to the manual provided with the option.
Wiring for CIMR-LE2A0018 to 2A0225, 4A0009 to 4A0140
Figure 55
Figure 62 Using a Battery for the DC Bus and 24 V Power Supply Unit Option for the Control Circuit
Operation Sequence
Starting Rescued Operation
1.
Open contactor B and wait at least 5 seconds.
2. Set the input terminal programmed for Rescue Operation (H1- = 55).
3. Close contactors A and C.
4. Set the Up/Down command.
Ending Rescue Operation
1.
After the car has stopped, open contactors A and C.
2. Clear the input terminal set for Rescue Operation (H1- = 55).
3. Wait at least 0.5 s and then close contactor B to return to operation with normal power supply.
-
CN19
1
4
W/T3
V/T2
U/T1
R/L1
S/L2
T/L3
B1
+2
+1
B2
SC
S
3
to
S8
5 s
0.5 s
24 Vdc
L1
L2
L3
L1000A
Magnetic Contactor Sequence
Battery for DC bus
DC bus power supply
Battery for
control circuit
H1-ڧڧ = 55
(Rescue Operation)
200 V Class: 48 to 340 Vdc
400 V Class: 48 to 680 Vdc
Magnetic Contactor A
Magnetic Contactor B
Magnetic Contactor C
Control
circuit
Power supply
24 V
Power
Supply
Unit
H1-ڧڧ = 55
(Rescue Operation)
Magnetic Contactor B
Magnetic Contactor A
Magnetic Contactor C
YEA_comm