B Parameter Table
YASK AWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide 177
Parameter Table
B
F1-10
(389H)
Excessive Speed Deviation
Detection Level
Sets the speed deviation detection level as a percentage of the maximum output
frequency.
Default: 10%
Min: 0%
Max: 50%
F1-11
(38AH)
Excessive Speed Deviation
Detection Delay Time
Sets the time in seconds for a speed deviation situation to trigger a fault (dEv).
Default: 0.5 s
Min: 0.0 s
Max: 10.0 s
F1-14
(38DH)
PG Open-Circuit Detection
Time
Sets the time required to trigger a PG Open fault (PGo).
Default: 2.0 s
Min: 0.0 s
Max: 10.0 s
F1-18
(3ADH)
dv3 Detection Selection
0: Disabled
n: Sets the number of dv3 situations that may be detected before triggering an
actual dv3 fault.
Default: 10
Min: 0
Max: 10
F1-19
(3AEH)
dv4 Detection Selection
0: Disabled
n: Number of pulses that the A and B pulse are reversed that triggers dv4
detection.
Default: 128
Min: 0
Max: 5000
F1-20
(3B4H)
PG Option Card Disconnect
Detection 1
0: Disabled
1: Enabled
Default: 1
Min: 0
Max: 1
F1-29
(3BFH)
dEv Detection Condition
Selection
Selects when DEV is active.
0: After speed reference, soft starter output and motor speed have matched once.
1: After speed reference and soft starter output have matched once.
2: Always during Run
Default: 2
Min: 0
Max: 2
F1-50
(3D2H)
Encoder Selection
Selects the encoder connected the PG-F3 option.
0: EnDat 2.1/01, 2.2/01 Serial Communication + Sin/Cos
1: EnDat 2.2/22 Serial Communication
2: Hiperface
Default: 0
Min: 0
Max: 2
F1-51
(3D3H)
PGoH Detection Level
Sets the level for detecting PG Hardware Fault (PGoH). Available when F1-20 =
1
Default: 80%
Min: 1%
Max: 100%
F1-52
(3D4H)
Communication Speed of
Serial Encoder Selection
Selects the communication speed between the PG-F3 option and serial encoder.
0: 1M bps/9600 bps
1: 500k bps/19200 bps
2: 1M bps/38400 bps
3: 1M bps/38400 bps
Default: 0
Min: 0
Max: 3
F1-63
(2DFH)
PG-E3 R Track Selection
0: Disabled
1: Enabled
Default: 0
Min: 0
Max: 1
F1-66 to
F1-81
(B9AH to
BA9H)
PG-E3 Encoder Adjust 1 to 16
Sets encoder offsets 1 to 16 for the PG-E3 option card. These parameters are
automatically set by the execution of Auto-Tuning of PG-E3 encoder
characteristics.
Default: 0
Min: 0
Max: FFFF
<1> Default setting is determined by the control mode (A1-02).
<2> Setting range is 1 to 15000 ppr when the drive is set for CLV/PM.
No.(Addr.) Name Description Setting
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV

Related product manuals