B Parameter Table
YASK AWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide 185
Parameter Table
B
20 Drive Overheat Pre-alarm (oH)
Closed: Heatsink temperature exceeds the parameter L8-02 value.
2F Maintenance Period
Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require
maintenance.
30 During Torque Limit
Closed: When the torque limit has been reached.
33
Within Position Lock
Bandwidth
Closed: Position deviation is within the Position Lock Bandwidth.
37 During Frequency Output
Open: No frequency output from drive when stopped with baseblock, stopped with DC injection
braking during initial excitation, or stopped with short circuit braking.
Closed: Drive is outputting a frequency.
47 Input Phase Loss
Closed: Input phase loss has occurred
Open: Normal operation (no phase loss detected)
4E Braking Transistor Fault (rr)
Closed: The built-in dynamic braking transistor failed.
Note: This function is not available in models 2A0181 to 2A0432 and 4A0094 to 4A0260.
50 Brake Control
Close: Release brake
Open: Apply brake
51 Output Contactor Control
Closed: Close output contactor
52 Door Zone Reached
Closed: Indicates that the door zone has been reached.
53 Not Zero Speed
Closed: Speed is greater than the zero speed level set to S1-01
Open: Operating at zero speed level
54 Light Load Direction
Closed: Light load direction is up
Open: Light load direction is down
55
Light Load Direction Detection
Status
Closed: Ready for Light Load Direction Search
Open: Light Load Detection in progress
58 Safe Disable Status
Closed: Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open: Safe Disable terminals H1-HC and H2-HC are closed (normal operation)
5C
Motor Current Monitor
Open: Output current is greater than the value of L8-99
Closed: Output current is less than or equal to the value of L8-99
60 Internal Cooling Fan Alarm
Closed: Internal cooling fan alarm
61 Motor Pole Search Status
Closed: Motor pole search successful
H2 Multi-Function Digital Output Settings
H2-
Setting
Function Description
All Modes
common
_
All Modes
common
_
common
_
CLV
CLV/PM
V/f OLV
common
_
CLV
CLV/PM
V/f OLV
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
common
_
CLV
CLV/PM
V/f OLV

Related product manuals