7 Parameter Table
YASKAWA Europe TOEP C710616 92D AC Drive L1000H Quick Start Guide EN 34
E1-04
Maximum
Output
Frequency
V/f pattern settings
For linear V/f characteristics, set the same
values to E1-07 and E1-09. With these
settings, the drive will disregard the value
set to E1-08.
Parameters must be set so that:
E1-09 E1-07 E1-06 E1-04
E1-05
Maximum
Vo l t a g e
E1-06
Base
Frequency
E1-07
Mid Output
Frequency
E1-08
Mid Output
Frequency
Vo l t a g e
E1-09
Minimum
Output
Frequency
E1-10
Minimum
Output
Frequency
Vo l t a g e
E1-13 Base Voltage
Motor Parameters
E2-01 Rated Current
Motor data for Induction Motors.
E2-02 Rated Slip
E2-03
No-Load
Current
E2-04 Motor Poles
E2-05
Line-to-Line
Resistance
E2-06
Leakage
Inductance
Multi-Function Digital Inputs
H1-01 to
H1-08
DI S1 to S8
Function
Selection
Selects the function of terminals S1 to S8.
Note: Major functions are listed at the end of the table.
Multi-Function Digital Outputs
H2-01
DO M1/M2
Function
Sets the function for the relay output
M1-M2.
H2-02
DO M3/M4
Function
Sets the function for the photocoupler
output M3-M4.
H2-03
DO M5/M6
Function
Sets the function for the photocoupler
output M5-M6.
H2-04
DO P1
Function
Sets the function for the photocoupler
output P1.
H2-05
DO P2
Function
Sets the function for the photocoupler
output P2.
Note: Major functions are listed at the end of the table.
Multi-Function Analog Inputs
H3-01,
H3-09
Terminal A1,
A2 Signal
Level Sel.
0: 0 to 10 V
1: -10 to 10 V
H3-02,
H3-10
Terminal A1,
A2 Function
Selection
1F: Through mode
20: Temperature input
H3-03,
H3-11
Terminal A1,
A2 Gain
Setting
Sets the level of the input value selected in
H3-02 and H3-10 when 10 V is input at
terminals A1 and A2.
H3-04,
H3-12
Terminal A1,
A2 Bias
Setting
Sets the level of the input value selected in
H3-02 and H3-10 when 0 V is input at
terminals A1 and A2.
No. Name Description
Output Voltage (V)
Frequency (Hz)
E1-05
E1-13
E1-08
E1-10
E1-09 E1-07 E1-06 E1-04
Multi-Function Analog Outputs
H4-01,
H4-04
Terminal FM,
AM Monitor
Selection
Selects the data to be output through
multi-function analog output terminals FM
and AM.
H4-02,
H4-05
Terminal FM,
AM Gain
Sets the signal level for terminals FM and
AM that are equal to 100% of the monitor
output that has been selected.
H4-03,
H4-06
Terminal FM,
AM Bias
Sets the signal level for terminals FM and
AM that are equal to 0% of the monitor
value.
H4-07,
H4-08
Terminal FM,
AM Signal Sel.
0: 0 to 10 V
1: -10 to 10 V
Motor Protection
L1-01
Motor
Overload
Protection
Selection
0: Disabled
1: General purpose motor (self-cooled)
2: Drive dedicated motor with a speed range
of 1:10
3: Vector motor with a speed range of 1:100
L1-02
Motor
Overload
Protection
Time
Sets the motor overload protection time in
min. Normally no change is necessary.
Stall Prevention
L3-01
Stall
Prevention
Selection
during
Acceleration
0: Disabled - Motor accelerates at active
acceleration rate and may stall with too
heavy load or too short accel time.
1: General Purpose - Hold acceleration
when current is above L3-02.
2: Intelligent - Acceleration in the shortest
possible time.
L3-02
Stall Prev.
Level during
Accel.
Sets the current level for stall prevention
during acceleration.
Torque Limit
L7-01 to
L7-04
Torque Limit Available in Customer Access Level.
Ambient Temperature
L8-12
Ambient
Temperature
Available in Customer Access Level.
Digital Operator Display Selection
o1-03
Digital
Operator
Display Unit
Selection
0: 0.01 Hz
1: 0.01%
2: r/min
Input Data - Teaching Function
P1-01
Hydraulic Oil
ISO VG
Number
0: Manual Setting,
1: ISO VG 22,
2: ISO VG 32,
3: ISO VG 46,
4: ISO VG 68
P1-02*
Temperature at
100 cSt
Manual or preselected by P1-01
P1-03*
Temperature at
25 cSt
Manual or preselected by P1-01
* Only available when setting A1-01 = 2.
P1-04 Ram Diameter Elevator data
P1-05
Number of
rams
Elevator data
P1-06
Suspension
ratio
Elevator data
P1-07
Empty car
static pressure
Elevator data
No. Name Description

Related product manuals