7 Parameter Table
EN 35 YASKAWA Europe TOEP C710616 92D AC Drive L1000H Quick Start Guide
P1-08 Pay load Elevator data
P1-09
Dynamic
pressure
increase
Elevator data
P1-11
Flow at 100cSt
& at max.
pressure
Pump data:
refer to the parameter data supplied with the
valve package or use the following web
page to calculate the values:
http://www.blain.de/calc
P1-12
Flow at 100cSt
& at max.
pressure
P1-13
Pump Rated
Speed
P1-14
Flow at empty
car pressure &
at 100cSt
Pump data
For valves from manufacturer "Blain
Hydraulics GmbH", use calculation tool in
the internet:
http://www.blain.de/calc
or the iPhone App “Blain Calculator”
P1-15
Flow at 1 bar
pressure & at
100cSt
P1-16 Nominal Speed Elevator data
P1-17
Intermediate
Speed
Elevator data
P1-18
Inspection
Speed
Elevator data
P1-19
Leveling
Speed
Elevator data
Down Travel Control
P2-01
Down Control
Initialization
Temperature
Enables down travel control
P2-03
Down Energy
Factor
Determines the minimum pump frequency
during down travel control. Modes:
P2-03 = 0.0 Energy Saving
P2-03 > 0.0 Normal
P2-04
Down Ramp
Time 1
Time for calculated acceleration ramp 1
during down travel control sequence.
P2-06
Down Ramp
Time 2
Time for calculated acceleration ramp 2
during down travel control sequence.
P2-07
Down
Deceleration
Frequency
Gain
Factor for adjusting the deceleration
frequency level in down travel control.
P2-08
Down Speed
Torque
Reference
Torque reference value for Down Travel
Control
P2-09
Down Torque
Gain
Correction
Factor
Gain value, applied to the torque gain in
case of down travel control.
P2-10
Down
Temperature
Gain
Correction
Factor
Gain value, applied to the temperature gain
in case of down travel control.
P2-11
Down
Deceleration
Leakage Gain
Gain value, applied to the pump leakage at
deceleration.
P2-12
Down
Leveling
Control Wait
Time
Wait time for leveling travel control.
No. Name Description
P2-13
Down
Leveling
Control Step
Frequency
Step frequency for leveling travel control.
P2-14
Down leveling
control step
time
Step time for leveling travel control.
P2-15
S Curve
Characteristic
2 at Decel Start
S curve characteristic 2 at deceleration start.
P2-16
S Curve
Characteristic
2 at Decel End
S curve characteristic 2 at deceleration end.
P2-17
S Curve
Characteristic
3 at Decel Start
S curve characteristic 3 at deceleration start.
P2-18
S Curve
Characteristic
3 at Decel End
S curve characteristic 3 at deceleration end.
P2-19
Down Valve
Open Delay
Delay for closing digital output H2-0 = 40
after H1-0 = 83h is closed.
Output Data - Teaching Functions
P3-01
Nominal Speed
Frequency -
Empty
Teaching output.
Frequency values.
P3-02
Intermediate
Speed
Frequency -
Empty
P3-03
Inspection
Speed
Frequency -
Empty
P3-04
Leveling
Speed
Frequency -
Empty
P3-07
Pump Leakage
Empty
P3-10
Nominal Speed
Torque
Reference -
Empty [%] at
P3-16
Teaching output
P3-11
Intermediate
Speed Torque
Ref-erence -
Empty
P3-12
Inspection
Speed Torque
Reference -
Empty
P3-13
Leveling
Speed Torque
Reference -
Empty
P3-16
Temperature
Reference
No. Name Description