Maintenance and inspection
9 - 58
4. Connect the new battery pack to the unoccupied connector on the board.
Fig. 9-5: Battery pack connections
5. Remove the old battery pack from the battery holder.
6. Mount the new battery pack to the battery holder.
NOTICE
The absolute encoder data will be lost
Never remove old battery pack before having installed new battery pack.
7. Please remove old battery pack plug from circuit board.
NOTICE
Make sure that no wires are pinched when you install the battery pack and the cover plate
again.
8. Please apply Teroson Plast sealing compound (material no. 143813) to thread part of
screws.
Exchanging the battery unit iscompleted after reinstalling the cover plate on the plug plate.
Old battery pack before replacement Plug
New battery pack Circuit board
See exchange, step 6 See exchange, step 7