Table 13. Differences in main circuit terminal size, shape, and wire gauge for single-phase 200 V class
Model
Drive capacity
V1000: Type
GA500: Type
Terminal
Connectable
wire gauge size:
mm
2
Terminal Screw
Tightening
torque: N-m
(lbfin)
Size
Shape
V1000
BA0001
BA0002
BA0003
L
0.75-2
M3.5
0.8-1.0
(7.1-8.9)
N
-, +1
B1, B2
GA500
B001
B002
B004
L
0.75-2
M3
0.5-0.6
(4.4-5.3)
N
-, +1
B1, B2
M3.5
0.8-1.0
(7.1-8.9)
V1000
BA0006
BA0010
BA0012
L
2-5.5
M4
1.2-1.5
(10.6-13.3)
N
-, +1
B1, B2
GA500
B006
L
2-5.5
M3
0.5-0.6
(4.4-5.3)
N
-, +1
B1, B2
M4
1.2-1.5
(10.6-13.3)
B010
L
2-5.5
M3
0.5-0.6
(4.4-5.3)
N
-, +1
B1, B2
M4
1.2-1.5
(10.6-13.3)
B012
L
2-8
M4
1.5-1.7
(13.5-15)
N
2-5.5
-, +1
2-8
B1, B2
2-5.5
1.2-1.5
(10.6-13.3)
V1000
BA0018
L
3.5-8
M5
2.3-2.5
(19.8-22)
N
-, +1
B1, B2
2.0 to 2.5
(17.7-22.1)
GA500
B018
L
3.5-14
M4
1.5-1.7
(13.5-15)
N
2-8
-, +1
3.5-14
B1, B2
2-8
3.5-8
M6
2.0 to 2.5
(17.7-22.1)