EasyManua.ls Logo

Yealink SIP-T21 E2

Yealink SIP-T21 E2
1126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Administrators Guide for SIP-T2 Series/T19(P) E2/T4 Series/T5 Series/CP860/CP920 IP Phones
648
Parameters
Permitted Values
Default
Configures the period (in seconds) of ACD subscription for account X.
X ranges from 1 to 16 (for SIP-T54S/T48G/T48S/T46G/T46S/T29G)
X ranges from 1 to 12 (for SIP-T52S/T42G/T42S)
X ranges from 1 to 6 (for SIP-T41P/T41S/T27P/T27G)
X ranges from 1 to 3 (for SIP-T40P/T40G/T23P/T23G)
X ranges from 1 to 2 (for SIP-T21(P) E2)
X is equal to 1 (for SIP-T19(P) E2/CP860/CP920)
Note: It works only if the value of the parameter account.X.acd.enable is set to 1
(Enabled).
Web User Interface:
Account->Advanced->ACD Subscribe Period(120~3600s)
Phone User Interface:
None
acd.auto_available
0 or 1
0
Description:
Enables or disables the IP phone to automatically change the status of the ACD agent to
available after the designated time.
0-Disabled
1-Enabled
Note: It works only if the value of the parameter account.X.acd.enable is set to 1
(Enabled).
Web User Interface:
Features->ACD->ACD Auto Available
Phone User Interface:
None
acd.auto_available_timer
Integer from 0 to 120
60
Description:
Configures the interval (in seconds) for the status of the ACD agent to be automatically
changed to available.
Note: It works only if the values of parameters account.X.acd.enable” and
“acd.auto_available” are set to 1 (Enabled).
Web User Interface:
Features->ACD->ACD Auto Available Timer (0~120s)