EasyManuals Logo

Yealink SIP-T48U Administrator's Guide

Yealink SIP-T48U
572 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
Phone Provisioning
74
MAC-local CFG File
MAC-local CFG file, which is named after the MAC address of the IP phone. For example, if the MAC address of an
IP phone is 00156574B150, the name of the MAC-local CFG file is 00156574b150-local.cfg (lowercase). It contains
changes associated with a non-static parameter that you make via the web user interface or phone user interface
(for example, changes for time and date formats, ring tones, and DSS keys).
This file generates only if you enable the provisioning priority mechanism. It is stored locally on the IP phone and
you can upload it to the provisioning server each time the file updates. This file enables the users to keep their per-
sonalized configuration settings, even though the IP phone performs auto provisioning.
This file supports the overwrite mode. That is, you can clear the user's personalized configurations settings by delet-
ing a parameter or leaving the value of a parameter blank in the MAC-local CFG file on the server. Note that if there
is no MAC-local CFG file found on the server, the MAC-local CFG file on the phone will not be cleared.
Note: The non-static changes that you made before enabling the provisioning priority mechanism are not saved in the gen-
erated MAC-local file, but the previous settings still take effect on the phone. The static changes are never be saved to the
<MAC>-local.cfg file.
The provisioning priority mechanism is enabled by the parameter “static.auto_provision.custom.protect”.
Configuration File Customization
You can create some new CFG files by making a copy and renaming the configuration template file (for example,
sip.cfg, account.cfg). You can rearrange the parameters in the configuration template file and create your own con-
figuration files with parameters you want. This flexibility is especially useful when you want to apply specific settings
to a group of phones.
Topic
Customizing a Configuration File
Customizing a Configuration File
1.
Copy and rename a configuration template file. For example, sip.cfg.
2.
Rearrange the parameters in the sip.cfg, and set the valid values for them.
For example:
phone_setting.contrast = 7
local_time.time_format = 1
account.1.anonymous_call = 1
account.2.dnd.enable = 1
features.dnd.enable = 0
3.
To specify parameters for specific phone models, add specific phone models in the front of the corresponding
parameters. Multiple phone model names are separated by commas.
For example:
[T46S,T48S]voice_mail.number.1 = *5
[T27G]account.1.dnd.enable = 1
[T46S]account.2.dnd.enable = 1
[T48S]features.dnd.enable = 0
## These parameters only apply to their own specific phone models.
4.
Save the configuration file and place it on the provisioning server.
Related Topic
Configuration File Attributes
Configuration File Attributes
The following table lists the attributes you need to know in the configuration template file.

Table of Contents

Other manuals for Yealink SIP-T48U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T48U and is the answer not in the manual?

Yealink SIP-T48U Specifications

General IconGeneral
Handset typeWired handset
Product typeIP Phone
Product colorGray
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Expansion module supportYes
Ethernet LAN (RJ-45) ports2
Display diagonal7 \
Display resolution800 x 480 pixels
Lines quantity- lines
Phonebook capacity1000 entries
Number of VoIP accounts16
Voice codecsAGC, AJB, AMR-WB, CNG, G.711, G.722, G.723.1, G.726, G.729ab, VAD, iLBC
Security algorithmsAES, HTTPS, SRTP, TLS
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet LAN interface typeGigabit Ethernet
Front camera-
AC adapter input voltage100 - 240 V
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 95 %
Keypad number of keys29
Number of handles included1 pc(s)
Harmonized System (HS) code85171800
Weight and Dimensions IconWeight and Dimensions
Width226 mm
Height185 mm

Related product manuals