5) Conrmationofadaptermountingscrew
Afterinstallationofthemagneticowmeter,be
sure to retighten the adapter mounting screw 
according to Table 3.3.18 or Table 3.3.19.
Besuretoconrmthatleakagefromadapter
connectionpointdoesnotoccurbyllingthepipe
oftheowtubewithuid.
NOTE
The sleeve, nut, and gasket are not provided with the 
owmeter,andmustbeprovidedbytheuser.
Gasket
Sleeve
Adapter for union connection
Nut
Figure 3.3.7   Mounting Procedure for Union Connection 
Type
(c)  Butt weld adapter type
(process connection codes: KDB and KKB)
1)  Removing adapter
Remove the butt weld adapter by loosening the 
mounting screws.
2)  Welding ferrule or sleeve
Weld a ferrule, a sleeve, or an alternative
(provided by the user) to the butt weld adapter.
IMPORTANT
•  Be sure to weld the ferrule, the sleeve, or the 
alternative after removing the butt weld adapter 
fromtheowmeteritself.
•  When welding the ferrule, the sleeve, or the 
alternative, pay attention to the edge preparation, 
level differences between them and the piping, and 
the welding current to avoid deforming the piping 
orcausingstagnationportionoftheuid.
3)  Installing butt weld adapter
Installagaskettotinthegrooveofthebuttweld
adapter, and tighten the mounting screws.
CAUTION
•  In case of standard gasket (EPDM rubber), tighten 
the adapter mounting screw according to the 
torque values in Table 3.3.18.
•  In case that optional code GH (Silicon rubber) 
is selected, tighten the adapter mounting screw 
according to the torque values in Table 3.3.19.
•  Tighten the adapter mounting screw in diagonal 
order step by step.
• Aftertighteningofscrew,conrmthatgaskets
protrude inside adapter. Protruding of gasket is 
necessary to keep the sanitary requirements.
Table 3.3.18   Tightening Torque Values of adapter for EPDM 
rubber gasket
Tightening torque values (N-m / {kgf-cm} / [in-lbf])
Gasket 
typeSize  
mm (inch)
EPDM rubber (standard)
15 (0.5), 25 (1.0),  
32 (1.25), 40 (1.5)
3.0 to 3.5 / {30.59 to 35.69} / [26.55 to 30.98]
50 (2.0), 65 (2.5) 4.5 to 5.0 / {45.89 to 50.99} / [39.83 to 44.25]
80 (3.0) 8.0 to 9.0 / {81.58 to 91.78} / [70.81 to 79.65]
100 (4.0), 125 (5.0) 10 to 11 / {102.0 to 112.2} / [88.50 to 97.35]
Table 3.3.19   Tightening Torque Values of adapter for 
silicon rubber gasket
Tightening torque values (N-m / {kgf-cm} / [in-lbf])
Gasket 
typeSize  
mm (inch)
Silicon rubber (optional code GH)
15 (0.5), 25 (1.0),  
32 (1.25), 40 (1.5)
2.0 to 2.5 / {20.39 to 25.49} / [17.70 to 22.13]
50 (2.0), 65 (2.5), 80 (3.0) 4.0 to 4.5 / {40.79 to 45.89} / [35.40 to 39.83]
100 (4.0), 125 (5.0) 6.0 to 6.5 / {61.18 to 66.28} / [53.10 to 57.53]
4) Mountingowmetertopiping
Connecttheowmetertothepipinginamanner
appropriate to the ferrule, the sleeve, or the 
alternative that has been welded to the adapter.
5) Conrmationofadaptermountingscrew
Afterinstallationofthemagneticowmeter,be
sure to retighten the adapter mounting screw 
according to Table 3.3.18 or Table 3.3.19.
Besuretoconrmthatleakagefromadapter
connectionpointdoesnotoccurbyllingthepipe
oftheowtubewithuid