EasyManuals Logo

YOKOGAWA digitalYEWFLO Series User Manual

YOKOGAWA digitalYEWFLO Series
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
<APPENDIX 6. Enhanced ARITHMETIC (AR) BLOCK>
A6-4
IM 01F06F00-01EN
A6.3 Computation Section
A6.3.1 Computing Equations
This subsection shows computing equations used
in the computation section:
1) Flow compensation (linear)
func = PV × f
f = (t_1 / t_2)
2) Flow compensation (square root)
func = PV × f
f = sqrt(t_1 / t_2 / t_3)
3) Flow compensation (approximate expression)
func = PV × f
f = sqrt(t_1 × t_2 × t_3 × t_3)
4) Quantity of heat calculation
func = PV × f
f = (t_1 - t_2)
5) Multiplication and division
func = PV × f
f = ((t_1 / t_2) + t_3)
6) Average calculation
func = (PV + t_1 + t_2 + t_3) / N
where N: number of inputs
7) Summation
func = PV + t_1 + t_2 + t_3
8) Polynomial computation
func = PV + t_1
2
+ t_2
3
+ t_3
4
9) HTG-level compensation
func = (PV - t_1) / (PV - t_2)
10) Polynomial computation
func = PV + GAIN_IN_1 × PV
2
+ GAIN_IN_2 ×
PV
3
+GAIN_IN_3 × PV
4
* Precaution for computation
Division by “0”: If a value is divided by “0,”
the calculation result is
interpreted as 10
37
and,
depending with core, a plus
sign is added to it.
Negative square root: The square root of an
absolute value is extracted
and a minus sign is added to
it.
A6.3.2 Enhanced Computing Equations
32) Saturated steam (Temp): Saturated steam
density calculation (by temperature: based on
IAPWS-IF97)
func = PV x Correction Value
Correction Value: Saturated Steam density
calculated from t_1 (temp input).
Temperature range: 100 to 330°C
33) Saturated steam (Pressure): Saturated steam
density calculation (by pressure based on
IAPWS-IF97)
func = PV x Correction Value.
Correction Value: Saturated steam density
calculated from t_2 (Press. input).
Pressure range: 0.101417978 to
12.85752189 MPa
34) Superheat steam: Superheat steam density
calculation (based on IAPWS-IF97)
func = PV x Correction Value
Correction Value: Superheat steam density
calculated from t_1 (Temp. input) and t_2
(Press. input).
Temperature range: 100 to 330°C
Pressure range: 0.101417978 to 12.85752189
MPa
35) Gas temp pressure comp (Simple): Gas
temperature and pressure compensation
calculation. (Deviation factor: Fixed based on
Boyle-Charle's law.)
func = PV x Correction Value
Correction Value: Gas density ratio
f
/ρ
b
)
calculated from t_1 (Temp. input) and t_2
(Press. input), or, density at operating condition
f
).
36) Liquid temp comp (Simple): Liquid temperature
compensation calculation (based on API, JIS K
2249.)
func = PV x Correction Value
Correction Value: Liquid density at operating
condition calculated from t_1 (Temp. input).
37) Gas temp pressure comp (Detail): Gas
temperature and pressure compensation
calculation (approximating polynomial
calculation: 0 to 11).
func = PV x Correction Value
Correction Value: Gas density (Flow unit: Mass
ow rate) at operating condition calculated from
approximating polynomial calculation: 0 to 11,
or Density ratio (Flow unit: Volumetric ow rate
at normal condition) calculated from density at
normal condition.
38) Liquid temp comp (Detail): Liquid temperature
and pressure compensation calculation
(approximating polynomial calculation).
func = PV x Correction Value
Correction Value: Liquid density at operating
condition calculated from approximating
polynomial calculation: 0 to 3.

Table of Contents

Questions and Answers: