505428-YTG-V-0417
16 Johnson Controls Unitary Products
Cooling and Heating Ratings
LEGEND
EER = Energy Efficiency Ratio
AHRI = Air Conditioning and Refrigeration Institute
IPLV = Integration Part-Load Value
IEER = Integrated Energy Efficiency Ratio
Cooling And Heating Rating
Outdoor
Unit
Condensing Unit Only
Indoor
Unit
System Cooling Capacity
1
1
Certified in accordance with the Unitary Large Equipment certification program, which is based on AHRI Standard 340/360. (Except
YC300)
Heating Capacity
1
Rated
Airflow
(CFM)
Gross
Capacity
2
(MBH)
2
Condensing unit only ratings are at 45°F SST and 95°F entering-air temperature.
EER KW
Gross
Capacity
3
(MBH)
3
Gross capacity does not include heat added by blower motor. Refer to appropriate table for blower horsepower.
EER
IEER
(CV)
IEER w/
IntelliSpeed
High Outdoor Low Outdoor
Gross
Capacity
2
(MBh)
COP
Gross
Capacity
2
(MBh)
COP
PC090
4
N/A N/A N/A NC090 89 11.0 11.4 N/A 82 3.4 49 2.3 3000
PC090
4
N/A N/A N/A NL090 89 11.0 11.4 12.4 82 3.4 49 2.3 3000
PC120
4
4
Heat Pumps designed for matched systems only.
N/A N/A N/A NC120 120 10.8 11.4 N/A 109 3.3 63 2.25 3900
PC120
4
N/A N/A N/A NL120 120 10.8 11.4 13.5 109 3.3 63 2.25 3900
PC180
4
N/A N/A N/A NC180 180 10.6 12.0 N/A 168 3.2 104 2.3 5800
PC180
4
N/A N/A N/A NL180 180 10.6 12.0 13.3 168 3.2 104 2.3 5800
PD180
4
N/A N/A N/A ND180 174 10.6 11.4 N/A 160 3.4 100 2.25 6000
PD180
4
N/A N/A N/A NM180 174 10.6 11.4 14 160 3.4 100 2.25 6000
PD240
4
N/A N/A N/A ND240 230 10.6 11.2 N/A 220 3.3 130 2.2 8000
PD240
4
N/A N/A N/A NM240 230 10.6 11.2 13.3 220 3.3 130 2.2 8000
YC090 85 12.4 6.8 NC090 90 11.5 12.5 N/A N/A N/A N/A N/A 3000
YC090 85 12.4 6.8 NC120 95 11.9 12.7 N/A N/A N/A N/A N/A 3000
YC090 85 12.4 6.8 NL090 90 11.5 12.5 13.5 N/A N/A N/A N/A 3000
YC090 85 12.4 6.8 NL120 95 11.9 12.7 13.7 N/A N/A N/A N/A 3000
YC120 110 11.9 9.3 NC120 120 11.0 11.2 N/A N/A N/A N/A N/A 4000
YD120 108 11.8 9.1 ND120 120 11.0 11.2 N/A N/A N/A N/A N/A 4000
YC120 110 11.9 9.3 NL120 120 11.0 11.2 12.7 N/A N/A N/A N/A 4000
YD120 108 11.8 9.1 NM120 120 11.0 11.2 12.7 N/A N/A N/A N/A 4000
YC150 133 11.5 11.6 NC180 148 11.0 12.3 N/A N/A N/A N/A N/A 5000
YD150 136 11.8 11.5 ND180 150 11.0 11.5 N/A N/A N/A N/A N/A 5000
YC150 133 11.5 11.6 NL180 148 11.0 12.3 14.0 N/A N/A N/A N/A 5000
YD150 136 11.8 11.5 NM180 150 11.0 11.5 12.8 N/A N/A N/A N/A 5000
YC180 160 12.0 13.4 NC180 180 11.2 12.2 N/A N/A N/A N/A N/A 6000
YD180 166 13.4 12.3 ND180 180 11.0 12.2 N/A N/A N/A N/A N/A 6000
YC180 160 12.0 13.4 NL180 180 11.2 12.2 14.0 N/A N/A N/A N/A 6000
YD180 166 13.4 12.3 NM180 180 11.0 12.2 14.0 N/A N/A N/A N/A 6000
YC240 233 13.2 17.5 NC240 236 11.0 11.2 N/A N/A N/A N/A N/A 7600
YD240 222 12.8 17.3 ND240 240 11.0 11.9 N/A N/A N/A N/A N/A 8000
YC240 233 13.2 17.5 NL240 236 11.0 11.2 13.0 N/A N/A N/A N/A 7600
YD240 222 12.8 17.3 NM240 240 11.0 11.9 13.4 N/A N/A N/A N/A 8000
YC300 271 11.4 23.7 NC300 290 10.2 10.8 12.2
5
5
Requires field installed VFD kit.
N/A N/A N/A N/A 10000