6 PROBLEM/CAUSE/REMEDY
Problem Cause Remedy
Display o and buttons not working
Power failure Check that the power cable is connected
Faulty connection of display to board
Check that the display and board are connected
properly
Failed ignition Excessive pellet build-up in brazier Clean the brazier
The boiler does not switch on automatically
The resistance does not reach operating tempera-
ture
Check wiring and fuses
Replace the resistance if faulty (performed by
assistance)
Resistance damaged or worn Replace the resistance
The pellets do not drop
IMPORTANT: unplug the appliance before:
Checking whether any pellets are stuck in the
chute
Checking whether the auger is blocked
Checking tightness of the door
Blockage of the boiler
Excessive use without cleaning the brazier Clean the brazier
Tank empty Load pellets in the tank
Auger without pellets
Fill the tank and follow the instructions for the rst
ignition of the boiler
The boiler blocks due to lack of pellet feed Technical problem with auger
IMPORTANT: unplug the appliance before:
Freeing the auger from any obstructions
Freeing the chute from any obstructions
Removing pellet dust build-up at the bottom of
the tank
The boiler clogs quickly with irregular combustion
Flue too long or obstructed
See boiler installation paragraph
Check that the ue is clean
Pellets too moist Check the quality of the pellets
Too many pellets in brazier Contact the authorised assistance centre
Wind against exhaust ow Check the wind barrier terminal and/or install it
Insucient exhaust in brazier
Check that the brazier and air exhaust duct are
positioned properly and clean
Contact the authorised assistance centre
The type of pellet used was changed Contact the authorised assistance centre
Smell of smoke in the room
The boiler goes out
Improper combustion
Contact the authorised assistance centre.Flue gas extraction fan malfunctioning
Flue installed improperly
tab. 7 list of problems/causes/remedies