EasyManua.ls Logo

Zapi EPS-BLI HYG - Page 47

Zapi EPS-BLI HYG
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AFMNA0AA – EPS-BLI HYG – User Manual Page – 47/75
28) KEY VOLTAGE MIN
Unit: Volt.
Minimum key voltage sensed by the E-steering controller.
29) CAP VOLTAGE
Unit: Volt.
DC-link capacitors voltage sensed by the E-steering controller.
30) CAP VOLTAGE MAX
Unit: Volt.
Maximum DC-link capacitors voltage sensed by the E-steering controller.
31) CAP VOLTAGE MIN
Unit: Volt.
Minimum DC-link capacitors voltage sensed by the E-steering controller.
32) PMSM TEACH STAT.
Unit: number.
Status of the PMSM auto-teaching.
33) CPU TIME F US
Reserved for internal Zapi technicians.
34) CPU TIME M US
Reserved for internal Zapi technicians.
35) ROTOR ANGLE
Unit: degrees.
Real-time angular position of the rotor.
36) P SENS ERR REG
Unit: number.
Count of the feedback sensor errors.
37) P SENS AGC
Unit: number.
Real-time gain of the feedback sensor.

Table of Contents