119
Troubleshooting
Printer Diagnostics
3/27/07 ZM400/ZM600 User Guide 79695L-001 Rev. A
FEED and PAUSE Self Test
Performing this self test temporarily resets the printer configuration to the factory default
values. These values are active only until power is turned off unless you save them
permanently in memory. If the factory default values are permanently saved, a media
calibration procedure must be performed.
To perform a FEED and PAUSE self test, complete these steps:
1. Turn off (O) the printer.
2. Press and hold FEED and PAUSE while turning on (I) the printer.
3. Hold FEED and PAUSE until the first control panel light turns off.
The printer configuration is temporarily reset to the factory default values. No labels print
at the end of this test.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra Z Series ZM600 and is the answer not in the manual?

Zebra Z Series ZM600 Specifications

General IconGeneral
Memory16 MB SDRAM; 8 MB Flash
Print MethodThermal transfer and direct thermal
Print Width4.09 inches (104 mm)
Resolution203 dpi/8 dots per mm 300 dpi/12 dots per mm (optional)
ConnectivityUSB, Serial, Parallel, Ethernet
Media SensorsReflective Transmissive
Media Typesdie-cut, continuous, thermal, tag
Ribbon Width2 in./51 mm to 4.33 in./110 mm
Ribbon Length450 m/1476 ft
Optional ConnectivityZebraNet 10/100 Print Server
Operating Temperature40°F to 104°F/5°C to 40°C
Storage Temperature-40°F to 140°F/-40°C to 60°C
Humidity20% to 85% non-condensing
Power Requirements90-265 VAC, 47-63 Hz