TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
12.00
12.75
8.00
10.00
Equipment Ground
TB1
TB2
OPTIONAL
INTRINSICALLY
SAFE BARRIER
Equipment
Ground
Door
Gasket
PANEL CUTOUT
7.25" ± .03"
X
3.65" ± .03"
Ø0.31
2.00
2.00
L1
L2/Neut
INPUT POWER
115 / 230 VAC, 1 PHASE, 50/60 Hz
Chassis Ground
Motor Armature Leads
Motor Field Leads
A2
A1
F1
F2
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
9
10
11
12
FEEDBACK
SIGNAL
INTER-
LOCK
ANALOG
INPUT
ANALOG
OUTPUT
+12 VDC
SIGNAL +
COMMON
SHIELD
ROMOVE
JUMPER
INPUT +
COMMON
OUTPUT +
SHIELD
J 2
J 1
J 3
J 4
NOTES:
1. FOR INTERCONNECT WIRING BETWEEN ZeDRIVE
AND TERMINAL STRIPS, REFER TO NEXT PAGE. IN-
TERCONNECT WIRING TO BE INSULATED COPPER
CONDUCTOR, RATED AT 600V, 90 DEGREES CENTI-
GRADE.
2. COMMON AND GROUND CONNECTIONS ON THE
ZeDRIVE ARE OF DIFFERENT POTENTIAL. KEEP
SEPARATE.
3. TERMINAL STRIPS ARE IEC TYPE.
4. NEMA 12 CABINET, 12"H X 10"W X 8"D.
NOTES:
MOTOR ARMATURE AND FIELD LEADS
MUST BE RUN SEPERATE FROM
SHIELDED SIGNAL CABLES TO AVOID
SIGNAL NOISE IN FEEDBACK.