53
TRACTOR OPERATION 
E204 E205 E206 
IF THE ENGINE DOES NOT START 
Turn the key into position "0", wait 30 
seconds and repeat the start.  
Maximum 6 starting cycles are allowed 
(15 seconds starting and 30 second 
interruption make one cycle). Further 
engine starting attempt is allowed after 
cooling down of starter motor to the 
ambient temperature. 
Never help the stopping engine 
by the starter motor. It may be 
suffer damage this way. 
 
 
 
 
 
 
SIGNALLING OF GLOWING SYSTEM 
FAILURES 
Flashing of the glowing indicator light 
indicates failure in the glowing system. 
-  If the glowing indicator light is flashing 
once in a second with the stopped en-
gine, glowing will take place in emer-
gency regime as at low temperature 
regardless to coolant temperature. 
-  If the glowing indicator light is flashing 
twice in a second with the stopped en-
gine, the glowing is put of operation. 
-  If the glowing indicator light is flashing 
permanently with the engine running, 
failure of the glowing regulator oc-
curred and glowing was not finished. It 
is necessary to correct the failure im-
mediately, because there is danger of 
battery discharging. 
STARTER MOTOR HANDLING 
It is forbidden to start the trac-
tor by short circuit of starter 
motor connectors! 
Start the tractor from the 
driver’s seat only! 
When handling or repairing the 
starter motor, remember to dis-
connect the negative battery 
terminal and move all gearshift 
levers into neutral position, in-
cluding PTO shaft engagement! 
Starter motor connectors are  
covered with caps.