HRM
ERROR MESSJlGES:
Zilog
HRM
SMDMEDIA
displays
and
logs
error
messages
with
the
for-
mat
described
in
the
INTRODUCTION
TO
SMD
DIAGNOSTICS.
The
possible
contents
of
the
Operation
Field
are:
OPERATION
FIELD
Field
Contents
WRITE
TRK,xxxx
READ
IRK,
xxxx
Explanation
Error
occurred
while
writing
a
track.
The
data
pattern
written
replaces
"xxxx"
(hexadecimal).
Error
occurred
while
reading
a
track.
The
data
pattern
l"ead
replaces
"xxxx"
(hexadecimal).
SMDMEDIA
will
also
display
the
following
message:
COMPARE
WR:<ws>woff:wd
RD:<rs>roff:rd
DISK:u,cccc,hh,ss
A
mismatch
was
found
between
a
buffer
written
and
a
buffer
read
from
the
same
disk
a~dress.
The
mismatch
was
found
at
t~e
write
and
read
.buffer
addresses
given
by
"ws",
.
"woff"
(write
segment
(decimal)
and
offset
(hex»
and
"rs",
"roff"
(read
segment
and
offset).
The
data
written
replaces
"'wd"
(hexadecimal).
The
mismatch.ing
data
read
t'eplaces
"rdu
(also
hexadecimal).
LAP SUMMARY:
At
the
conclusion
of
each
complete
repetition
of
SMDMEDIA,
a
lap
summary
table
is
displayed.
This
table
is
described
in
the
INTRODUCTION
TO
SMD
DIAGNOSTICS.
A-50
Zilog