EasyManuals Logo

Zoom GFX-707 User Manual

Zoom GFX-707
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
In the factory default condition, patches are switched as soon as you make the selection, resulting
in an immediate change in the sound. This is called "Direct Load". If you want to change to a distant
patch (for example from patch A1 to patch E5), all the intermediate patches will briefly change the
sound, which may not be desirable. In such a case, you can reserve the patch and cause the patch
change to be delayed until confirmed by you. This function is activated as follows;
1
In play mode, press the EDIT (CANCEL) key.
2 Use the MODULE / keys to cause the
TOTAL module LED to light up.
3 Use the TYPE (BANK) / keys to cause
the indication "DIRLOD" (Direct Load) to
appear on the display.
This parameter determines whether the sound is
switched immediately when a patch is selected.
4 Turn parameter knob 1 so that the
BANK/PATCH indicator shows "oF".
5 Press the EDIT (CANCEL) key once more.
The unit returns to the play mode, and reserving
a patch is now possible. When a new patch is
selected in this condition, the BANK/PATCH
indicator and the patch name on the display are
flashing, but the sound does not change yet.
This shows that the unit is waiting for
confirmation from the user.
To confirm the patch change, press both /
foot switches at the same time. The
BANK/PATCH indicator and display indication
stop flashing, and the sound of the new patch
becomes active.
To return to the original operation mode, set
the DIRLOD parameter to "on".
The DIRECT LOAD setting is stored
automatically by the unit. There is no need to
perform any steps for storing.
Reserving the Next Patch (DIRECT LOAD)
14
Listening to Patches (Play Mode Operation)
ZOOM GFX-707
BANK PATCH
(
VALUE
)
BOTH EDITED
BANK PATCH
(
VALUE
)
BOTH EDITED
BANK PATCH
(
VALUE
)
BOTH EDITED
BANK PATCH
(
VALUE
)
BOTH EDITED
MODULE
(
ON/OFF
)
COMP•DIST
ZNR/EQ
MOD REV TOTAL
TYPE
(BANK)
(
GROUP
)
BANK PATCH
(
VALUE
)
BOTH EDITED
PATCH NAME
BANK PATCH
(
VALUE
)
BOTH EDITED
PARM1 knob
Confirm
BANK PATCH
(
VALUE
)
BOTH EDITED
BANK PATCH
(
VALUE
)
BOTH EDITED
HINTHINT
Fixing the Bank (BANK HOLD)
In play mode, you can fix the bank so that only patches within that bank are switched.
1
In play mode, press the EDIT (CANCEL) key.
2 Use the MODULE / keys to cause the
TOTAL module LED to light up.
3 Use the TYPE (BANK) / keys to cause
the indication "DIRLOD" (Direct Load) to
appear on the display.
4 Turn parameter knob 2.
As soon as you operate parameter knob 2, the
display indication changes to "BNKHLD" (Bank
Hold). This parameter determines whether the
bank is fixed in play mode or not. The default
setting is "oF".
5 Keep on turning parameter knob 2 until the
BANK/PATCH indicator shows "on".
6 Press the EDIT (CANCEL) key once more.
The unit returns to the play mode. The BNKHLD
parameter setting is reset to "off" when the
GFX-707 is turned off and on again.
When Bank Hold is activated, repeatedly
pressing foot switch will switch patches only
within the current bank, as shown below.
In the Bank Hold condition, the bank can still
be switched with the TYPE (BANK) /
keys.
To return to the original setting, set the
BNKHLD parameter to "oF".
HINTHINT
TYPE
(BANK)
(
GROUP
)
BANK PATCH
(
VALUE
)
BOTH EDITED
PATCH NAME
BANK PATCH
(
VALUE
)
BOTH EDITED
PATCH NAME
PARM2 knob
BANK PATCH
(
VALUE
)
BOTH EDITED
BANK PATCH
(
VALUE
)
BOTH EDITED
BANK PATCH
(
VALUE
)
BOTH EDITED
BANK PATCH
(
VALUE
)
BOTH EDITED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zoom GFX-707 and is the answer not in the manual?

Zoom GFX-707 Specifications

Effect Specifications IconEffect Specifications
effect programs48 types
effect modules4 modules + amp simulator + ZNR
sampler function maximum recording time6 seconds
Memory and Processing IconMemory and Processing
patch memory user6 banks x 5 = 30
patch memory preset6 banks x 5 = 30
sampling frequency31.25 kHz
Conversion and DSP IconConversion and DSP
a/d conversion20-bit, 64-times oversampling
d/a conversion20-bit, 128-times oversampling
dspZOOM original ZFx-2
Input and Output IconInput and Output
guitar input nominal input level-20 dBm
guitar input input impedance470 kilohms
maximum output level+3 dBm
Display and Power IconDisplay and Power
display6-position alphanumeric LED display
power supply9 V DC, center minus, 300 mA
continuous operationapprox. 14 hours with alkaline batteries
Weight and Dimensions IconWeight and Dimensions
external dimensions235 mm (W) x 189 mm (D) x 54 mm (H)
weight740 g
batteriesIEC R6 (size AA) x 4

Related product manuals